Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 11(23)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36498661

RESUMO

BACKGROUND: The aim of this study is to describe, for the first time to our knowledge, the utilization of both two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) in successfully performing transcatheter mitral valve (MV) in bioprosthetic MV/MV annulopasty ring implantation using the apical approach in 12 patients (pts) with co-existing left atrial appendage (LAA) and/or LA (left atrium) body thrombus, which is considered a contraindication for this procedure. METHODS AND RESULTS: All pts were severely symptomatic with severe bioprosthetic MV stenosis/regurgitation except one with a previous MV annuloplasty ring and severe native MV stenosis. Thrombus in LAA and/or LA body was noted in all by 2D and 3DTEE. All were at high/prohibitive risk for redo operation and all refused surgery. Utilizing both 2D and 3DTEE, especially 3DTEE, guidewires and the prosthesis deployment system could be manipulated under direct vision into the LA avoiding any contact with the thrombus. The procedure was successful in all with amelioration of symptoms and no embolic or other complications over a mean follow-up of 21 months. CONCLUSION: Our study demonstrates the feasibility of successfully performing this procedure in pts with thrombus in LAA and/or LA body without any complications.

2.
Echocardiography ; 39(7): 1011-1027, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35088455

RESUMO

We describe the role of three-dimensional echocardiography in the assessment of the aortic valve and the aorta. The manuscript is heavily illustrated with figures and movie clips.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia Tridimensional , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Humanos
3.
Echocardiography ; 38(6): 1064-1069, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34019314

RESUMO

We report the incremental value of live/real-time three-dimensional transthoracic echocardiography (3DTTE) over two-dimensional transthoracic echocardiography (2DTTE) in making a definitive diagnosis of left ventricular endocardial rupture with myocardial dissection and contained apical epicardial rupture in an elderly male patient presenting with acute myocardial infarction. To the best of our knowledge, this has not been described previously.


Assuntos
Ecocardiografia Tridimensional , Infarto do Miocárdio , Idoso , Dissecação , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem
4.
Echocardiography ; 38(4): 693-696, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33749908

RESUMO

We describe an elderly male patient with two MitraClip devices, one fixed and the other detached, in whom live/real-time three-dimensional echocardiography (3DTEE) provided incremental value and additional information compared to two-dimensional transesophageal echocardiography (2DTEE). 3DTEE offered the ability to comprehensively assess the mitral valve (MV) utilizing full volume and multiplanar reconstruction (MPR) modes. 3DTEE proved useful in assessing the position of the properly attached and the partially detached MitraClip, including assessment of orifice size and degree of mitral regurgitation (MR). In addition, trapping of MV chordae by both clips was noted in the 3DTEE image dataset and confirmed at the time of surgery. Chordal trapping was not detected by 2DTEE. 3DTEE proved useful in more accurately estimating the severity of residual MR with the MitraClips in place since the regurgitant jet vena contracta (VC) could be viewed en face and VC area measured by planimetry in the correct imaging plane as compared to limited linear images from 2DTEE.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Idoso , Ecocardiografia Transesofagiana , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Reprodutibilidade dos Testes
5.
Echocardiography ; 37(12): 2130-2133, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33219626

RESUMO

We present an adult female in whom two-dimensional transthoracic echocardiography demonstrated encroachment of the thoracic spine on the left atrium (LA) resulting in a very small, compressed LA cavity by a prominent thoracic spine shadow. Computed tomography (CT) scan of the chest showed compression of the LA produced by localized anterior deformation of the thoracic spine which had resulted from blunt injury to her spine following a fall from a swing several years previously.


Assuntos
Apêndice Atrial , Ferimentos não Penetrantes , Adulto , Ecocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...